Ready2Go  UART  protocol
Ready2Go UART protocol
The UART protocol is available in two different versions: legacy and
CBOR based protocol.
Legacy
| Lock Server status | Command execution | 
| 0x00 | successful | 
| 0x01 - 0xFF | failed | 
CBOR based protocol
The CBOR Object Length is the number of bytes of the CBOR object. It is
coded in big-endian.
The CBOR object is a well formed object with a tag-value structure.
| Lock Server Status | 254 | 
| 0x00 | Command execution successful |  
| 0x01 - 0xFF | Command execution failed |  | UINT8 | 
| Command ID | 101 | The 4 digit code of the BlueID command Note: its value is the same of the tag used in the command response. | Text string | 
| Token ID | 250 | The command Token ID | Text string | 
| Mobile Device ID | 251 | The Mobile Device ID executing the command | Text string | 
| User Data | 252 | The user data is a byte array whose maximum length is 165 bytes. | Byte array |